Reviewed by Alex Morgan. Last updated: 11-26.
Your lab report arrived. It is full of numbers, abbreviations, and units, and it is not obvious whether your water is safe. This guide shows you how to read it.
The quick method: for each contaminant, check the result, the units, the reference limit, and whether the limit is about health or about taste and appearance. Anything above a health-based limit, or any positive bacteria result, needs prompt attention. Anything above an aesthetic limit is usually a nuisance that can be treated.
If you have not tested your water yet, start with How to Test Well Water.
Key Takeaways
- Check the units first. mg/L, µg/L, and ng/L differ by a factor of 1,000 each.
- Health-based (primary) limits matter more than aesthetic (secondary) limits.
- «ND» or «<» means not detected or below the reporting limit, which depends on the lab’s sensitivity.
- EPA limits are written for public systems. They are useful yardsticks for private wells but are not legally enforceable on them.
- A bad result is a reason to act, not to panic: confirm it, protect your household, and treat the cause.
What Is on a Well Water Test Report?
Every lab formats its reports differently, but most contain the same elements.
| Section | What it shows | What to check |
|---|---|---|
| Sample information | Name, address, date and time collected, sample location, date received | That the details are correct and the sample reached the lab within the holding time |
| Analyte | The contaminant or property tested (arsenic, nitrate, pH) | That every test you ordered is listed |
| Result | The amount found | The number and any flag next to it |
| Units | mg/L, µg/L, pCi/L, NTU, and so on | That you compare like with like |
| Reporting limit (or detection limit) | The smallest amount the lab can reliably measure | Whether «not detected» is meaningful for your needs |
| Reference limit | A standard or guidance level, often an EPA limit | Whether it is health-based or aesthetic |
| Method | The analytical method used | Mostly useful for professionals |
| Flags or notes | Warnings such as «exceeds limit» or «holding time exceeded» | Read every note |
Understanding the Units
Units are where most mistakes happen. A lead result of 0.015 mg/L and one of 15 µg/L are the same amount, while 15 mg/L would be a thousand times higher.
| Unit | Meaning | Equivalent | Used for |
|---|---|---|---|
| mg/L | Milligrams per liter | Parts per million (ppm) | Nitrate, iron, sulfate, TDS, hardness |
| µg/L | Micrograms per liter | Parts per billion (ppb); 1 mg/L = 1,000 µg/L | Arsenic, lead, uranium |
| ng/L | Nanograms per liter | Parts per trillion (ppt); 1 µg/L = 1,000 ng/L | PFAS |
| pCi/L | Picocuries per liter | Measure of radioactivity | Radon, radium, gross alpha |
| NTU | Nephelometric turbidity units | Cloudiness | Turbidity |
| Present/Absent or CFU/100 mL | Presence or count of bacteria | Colony-forming units per 100 mL | Coliform, E. coli |
| µS/cm | Microsiemens per centimeter | Electrical conductivity | Conductivity, a rough guide to mineral content |
| gpg | Grains per gallon | 1 gpg is about 17.1 mg/L | Hardness |
| pH units | Acidity scale | 7 is neutral | pH |
Two common conversion traps
- Nitrate «as N» vs «as nitrate.» The 10 mg/L limit refers to nitrate as nitrogen (nitrate-N). A report showing nitrate as NO₃ needs to be divided by 4.43 to compare it. For example, 44 mg/L nitrate as NO₃ is roughly 10 mg/L as nitrogen, which is right at the limit.
- Hardness in gpg vs mg/L. Water softener information often uses grains per gallon, while lab reports often use mg/L as calcium carbonate.
Primary, Secondary, and Other Types of Limits
Reports often cite different kinds of limits. They are not equally urgent.
| Term | What it means | Urgency |
|---|---|---|
| Primary standard (MCL) | A legally enforceable health-based limit for public water systems | High: exceeding it is a health concern |
| MCLG (goal) | A non-enforceable health goal, sometimes zero | Informational |
| Action level | A trigger for treatment or other action (used for lead and copper) | High |
| Secondary standard (SMCL) | A non-enforceable guideline for taste, odor, color, and staining | Low to moderate: aesthetic and equipment concerns |
| Health advisory | Non-enforceable guidance for some contaminants | Varies |
Because private wells are not covered by these rules, treat the numbers as benchmarks. Your state or county may have its own guidance, so check with your health department.
Safe Limits Chart for Common Well Water Contaminants
These are EPA standards or guidance for public systems, used here as yardsticks. Verify against current EPA and state sources before publishing or relying on them.
| Contaminant | Commonly used limit | Type | If your result is above the limit |
|---|---|---|---|
| Total coliform bacteria | Absent (none detected) | Health indicator | Do not drink untreated; see Coliform Bacteria in Well Water |
| E. coli | Absent (none detected) | Health | Treat as urgent; avoid drinking untreated water |
| Nitrate (as N) | 10 mg/L | Health | See High Nitrates in Well Water; use alternative water for infants |
| Nitrite (as N) | 1 mg/L | Health | Same as nitrate; consult your health department |
| Arsenic | 0.010 mg/L (10 µg/L) | Health | See Arsenic in Well Water |
| Lead | Goal zero; action level 0.015 mg/L (15 µg/L) for public systems | Health | Identify the plumbing source; see Lead in Private Well Water |
| Copper | Action level 1.3 mg/L | Health and staining | Check plumbing; consider pH treatment |
| Fluoride | 4 mg/L (primary); 2 mg/L (secondary) | Health and dental | Consult your health department and a treatment professional |
| Uranium | 30 µg/L | Health | Seek professional advice for treatment |
| Radium (226 + 228) | 5 pCi/L | Health | Seek professional advice for treatment |
| Gross alpha | 15 pCi/L | Health screening | Follow-up testing |
| Benzene (a VOC) | 5 µg/L | Health | Contact your health department; find the source |
| PFAS | Measured in ng/L; limits are evolving | Health | See PFAS in Well Water |
| Iron | 0.3 mg/L | Aesthetic | See how to remove iron |
| Manganese | 0.05 mg/L | Aesthetic (some health guidance exists) | Treatment is similar to iron |
| Sulfate | 250 mg/L | Aesthetic | Taste and laxative effect for newcomers |
| Chloride | 250 mg/L | Aesthetic | May signal road salt or septic influence |
| Total dissolved solids (TDS) | 500 mg/L | Aesthetic | Taste and scale; consider reverse osmosis for drinking water |
| pH | 6.5-8.5 | Aesthetic and corrosion | Low pH can corrode pipes; consider neutralizing treatment |
| Sodium | 20 mg/L (guidance for very low-sodium diets) | Dietary | Relevant if a doctor has limited your sodium |
| Hardness | No health limit | Aesthetic | See hard well water |
Hardness at a glance
| Hardness (mg/L as calcium carbonate) | Classification |
|---|---|
| 0-60 | Soft |
| 61-120 | Moderately hard |
| 121-180 | Hard |
| Over 180 | Very hard |
An Example Report, Line by Line
Here is an illustrative report excerpt. The numbers are made up to show how to read a real one.
| Analyte | Result | Units | Reporting limit | Reference limit | Flag |
|---|---|---|---|---|---|
| Total coliform | Present | P/A | n/a | Absent | Exceeds |
| E. coli | Absent | P/A | n/a | Absent | OK |
| Nitrate (as N) | 6.2 | mg/L | 0.1 | 10 | OK |
| Arsenic | 0.014 | mg/L | 0.001 | 0.010 | Exceeds |
| Iron | 0.8 | mg/L | 0.05 | 0.3 | Exceeds (secondary) |
| Manganese | ND | mg/L | 0.01 | 0.05 | OK |
| Hardness | 210 | mg/L | 5 | none | Very hard |
| pH | 7.1 | pH units | n/a | 6.5-8.5 | OK |
What this example tells us:
- Total coliform present, E. coli absent. Surface contamination may be reaching the well. Treat the water as unsafe to drink untreated, disinfect the system, and retest. See Coliform Bacteria in Well Water.
- Nitrate at 6.2 mg/L. Below the limit, but worth watching. Retest next year and look for an upward trend.
- Arsenic 0.014 mg/L (14 µg/L). Above the 10 µg/L limit. Stop drinking the water or use a certified treatment option, and consult your health department.
- Iron 0.8 mg/L. Above the aesthetic limit. Expect staining and metallic taste. This is treatable.
- Manganese ND. Not detected at the lab’s 0.01 mg/L reporting limit.
- Hardness 210 mg/L. Very hard. Scale buildup is likely, and a softener may help.
- pH 7.1. Normal.
What «ND», «<«, and Other Marks Mean
| Mark | Meaning |
|---|---|
| ND | Not detected: below the lab’s detection limit |
| < 0.5 | Less than the reporting limit of 0.5: the lab cannot reliably measure below this |
| J or «estimated» | The value is between the detection limit and the reporting limit and is approximate |
| «Holding time exceeded» | The sample sat too long before analysis; the result may be unreliable |
| «Improper container» or «temperature exceeded» | The sample may have been compromised; consider retesting |
| «Exceeds» or an asterisk | The result is above the reference limit shown |
The reporting limit matters. «ND» is reassuring only if the lab can detect amounts below the level of concern. For a contaminant with a very low limit, ask the lab whether its sensitivity is adequate.
How to Interpret Your Report Step by Step
- Confirm the sample details. Name, address, date, and sample location should be right.
- Look for flags and notes. Read any warnings first.
- Check the units of every result before comparing it to a limit.
- Compare each result with its reference limit using the chart above, and note whether the limit is health-based or aesthetic.
- Read «ND» and «<» in context by checking the reporting limit.
- Compare with earlier reports. A result below the limit but rising each year is a signal to investigate.
- Sort the results into green, yellow, and red using the table below.
- Decide what to do next, and when to retest.
Green, Yellow, and Red: A Simple Triage
| Category | What it looks like | What to do |
|---|
| | Green | All results below limits; bacteria absent | Keep the report, retest on schedule. See How Often Should You Test Your Well Water? | | Yellow | Aesthetic limits exceeded (iron, manganese, hardness, sulfate, TDS, pH), or a health result approaching its limit | Not an emergency. Identify the cause, consider treatment, and retest. See Best Whole House Water Filter for Well Water | | Red | Bacteria present, or any health-based limit exceeded (nitrate, arsenic, uranium, VOCs, lead, PFAS) | Act promptly: use safe alternative water for drinking and cooking as advised, contact your health department, and pursue treatment or repair |
After any treatment or repair, retest to confirm the problem is solved.
Matching Results to Solutions
| Result | Typical treatment approach (confirm with a professional) |
|---|---|
| Bacteria | Disinfect the well and fix entry points; sometimes continuous treatment such as UV |
| Nitrate | Reverse osmosis or ion exchange; see Is Reverse Osmosis Worth It for Well Water? |
| Arsenic | Treatment chosen after identifying the form of arsenic present |
| Hardness | Water softener; see Water Softener vs Water Conditioner |
| Iron and manganese | Oxidizing filter or iron filter; see Iron Filter vs Water Softener |
| Low pH | Neutralizing filter |
| VOCs, PFAS, radiological | Specialized treatment after professional evaluation |
For pricing, see How Much Does a Whole House Water Filtration System Cost?
When to Retest or Get a Second Opinion
- After any treatment, repair, or disinfection.
- When a bacteria result is positive, retest following your health department’s instructions.
- When a result is surprising, such as a first-ever arsenic or nitrate detection. Contamination can change over time, and a repeat sample from a fresh collection can confirm it.
- When the lab flags a handling problem.
- When home test strips and the lab disagree. Trust the certified lab. See Well Water Test Kit vs Lab Test.
Frequently Asked Questions
What is a safe level of contaminants in well water?
There is no legal standard for private wells, but EPA drinking water standards for public systems are widely used as benchmarks. See the chart above, and check whether your state offers its own guidance.
What does ND mean on a water test?
ND means not detected. The contaminant was below the level the lab can measure. Check the reporting limit to judge how reassuring that is.
What is the difference between mg/L and ppm?
For water, they are equal. One mg/L is one part per million (ppm). Similarly, µg/L equals ppb and ng/L equals ppt.
Is my water safe if it only exceeds a secondary standard?
Usually, yes. Secondary standards are about taste, odor, color, and staining, not health. Exceeding them can still damage plumbing and appliances, so treatment may be worthwhile.
My nitrate result is 40. Is that a problem?
It depends on the form. If it is reported as nitrate-N, 40 mg/L is four times the 10 mg/L limit and is serious. If it is reported as nitrate (NO₃), 40 mg/L is about 9 mg/L as nitrogen, just under the limit. Check the unit line on your report, and ask the lab if you are unsure.
Does boiling fix a bad result?
Boiling kills bacteria, but it does not remove nitrate, metals, or most chemicals, and it can concentrate them. It is an emergency measure for bacteria only.
How long should I keep my reports?
Keep them for as long as you own the well. A series of reports shows trends, and they are useful when you sell the home. See Well Water Testing for Real Estate Transactions.
Who can help me interpret the results?
Start with the lab, which can explain the report. Your county or state health department can explain health implications and next steps, and a licensed water treatment professional can advise on treatment.
Final Thoughts
Reading a well water report comes down to four things: the number, the unit, the limit, and what kind of limit it is. Sort results into green, yellow, and red, act promptly on anything red, plan treatment for yellow, and retest after every fix.
Next step: if your results need work, compare options in Best Whole House Water Filter for Well Water, and plan your next test with How Often Should You Test Your Well Water?
Disclaimer: This article is for general information only and is not medical or legal advice. Standards and recommendations change and vary by state and local conditions. For health concerns or a positive test result, consult your local or state health department and a qualified professional.
Sources to cite and link when publishing (verify current versions): EPA National Primary and Secondary Drinking Water Regulations; EPA Private Drinking Water Wells; CDC Private Well Testing guidance; USGS water hardness reference; your state health department’s guidance for private wells.