How to Read Your Well Water Test Results (With Safe Limits Chart)

Reviewed by Alex Morgan. Last updated: 11-26.

Your lab report arrived. It is full of numbers, abbreviations, and units, and it is not obvious whether your water is safe. This guide shows you how to read it.

The quick method: for each contaminant, check the result, the units, the reference limit, and whether the limit is about health or about taste and appearance. Anything above a health-based limit, or any positive bacteria result, needs prompt attention. Anything above an aesthetic limit is usually a nuisance that can be treated.

If you have not tested your water yet, start with How to Test Well Water.

Key Takeaways

  • Check the units first. mg/L, µg/L, and ng/L differ by a factor of 1,000 each.
  • Health-based (primary) limits matter more than aesthetic (secondary) limits.
  • «ND» or «<» means not detected or below the reporting limit, which depends on the lab’s sensitivity.
  • EPA limits are written for public systems. They are useful yardsticks for private wells but are not legally enforceable on them.
  • A bad result is a reason to act, not to panic: confirm it, protect your household, and treat the cause.

What Is on a Well Water Test Report?

Every lab formats its reports differently, but most contain the same elements.

SectionWhat it showsWhat to check
Sample informationName, address, date and time collected, sample location, date receivedThat the details are correct and the sample reached the lab within the holding time
AnalyteThe contaminant or property tested (arsenic, nitrate, pH)That every test you ordered is listed
ResultThe amount foundThe number and any flag next to it
Unitsmg/L, µg/L, pCi/L, NTU, and so onThat you compare like with like
Reporting limit (or detection limit)The smallest amount the lab can reliably measureWhether «not detected» is meaningful for your needs
Reference limitA standard or guidance level, often an EPA limitWhether it is health-based or aesthetic
MethodThe analytical method usedMostly useful for professionals
Flags or notesWarnings such as «exceeds limit» or «holding time exceeded»Read every note

Understanding the Units

Units are where most mistakes happen. A lead result of 0.015 mg/L and one of 15 µg/L are the same amount, while 15 mg/L would be a thousand times higher.

UnitMeaningEquivalentUsed for
mg/LMilligrams per literParts per million (ppm)Nitrate, iron, sulfate, TDS, hardness
µg/LMicrograms per literParts per billion (ppb); 1 mg/L = 1,000 µg/LArsenic, lead, uranium
ng/LNanograms per literParts per trillion (ppt); 1 µg/L = 1,000 ng/LPFAS
pCi/LPicocuries per literMeasure of radioactivityRadon, radium, gross alpha
NTUNephelometric turbidity unitsCloudinessTurbidity
Present/Absent or CFU/100 mLPresence or count of bacteriaColony-forming units per 100 mLColiform, E. coli
µS/cmMicrosiemens per centimeterElectrical conductivityConductivity, a rough guide to mineral content
gpgGrains per gallon1 gpg is about 17.1 mg/LHardness
pH unitsAcidity scale7 is neutralpH

Two common conversion traps

  • Nitrate «as N» vs «as nitrate.» The 10 mg/L limit refers to nitrate as nitrogen (nitrate-N). A report showing nitrate as NO₃ needs to be divided by 4.43 to compare it. For example, 44 mg/L nitrate as NO₃ is roughly 10 mg/L as nitrogen, which is right at the limit.
  • Hardness in gpg vs mg/L. Water softener information often uses grains per gallon, while lab reports often use mg/L as calcium carbonate.

Primary, Secondary, and Other Types of Limits

Reports often cite different kinds of limits. They are not equally urgent.

TermWhat it meansUrgency
Primary standard (MCL)A legally enforceable health-based limit for public water systemsHigh: exceeding it is a health concern
MCLG (goal)A non-enforceable health goal, sometimes zeroInformational
Action levelA trigger for treatment or other action (used for lead and copper)High
Secondary standard (SMCL)A non-enforceable guideline for taste, odor, color, and stainingLow to moderate: aesthetic and equipment concerns
Health advisoryNon-enforceable guidance for some contaminantsVaries

Because private wells are not covered by these rules, treat the numbers as benchmarks. Your state or county may have its own guidance, so check with your health department.

Safe Limits Chart for Common Well Water Contaminants

These are EPA standards or guidance for public systems, used here as yardsticks. Verify against current EPA and state sources before publishing or relying on them.

ContaminantCommonly used limitTypeIf your result is above the limit
Total coliform bacteriaAbsent (none detected)Health indicatorDo not drink untreated; see Coliform Bacteria in Well Water
E. coliAbsent (none detected)HealthTreat as urgent; avoid drinking untreated water
Nitrate (as N)10 mg/LHealthSee High Nitrates in Well Water; use alternative water for infants
Nitrite (as N)1 mg/LHealthSame as nitrate; consult your health department
Arsenic0.010 mg/L (10 µg/L)HealthSee Arsenic in Well Water
LeadGoal zero; action level 0.015 mg/L (15 µg/L) for public systemsHealthIdentify the plumbing source; see Lead in Private Well Water
CopperAction level 1.3 mg/LHealth and stainingCheck plumbing; consider pH treatment
Fluoride4 mg/L (primary); 2 mg/L (secondary)Health and dentalConsult your health department and a treatment professional
Uranium30 µg/LHealthSeek professional advice for treatment
Radium (226 + 228)5 pCi/LHealthSeek professional advice for treatment
Gross alpha15 pCi/LHealth screeningFollow-up testing
Benzene (a VOC)5 µg/LHealthContact your health department; find the source
PFASMeasured in ng/L; limits are evolvingHealthSee PFAS in Well Water
Iron0.3 mg/LAestheticSee how to remove iron
Manganese0.05 mg/LAesthetic (some health guidance exists)Treatment is similar to iron
Sulfate250 mg/LAestheticTaste and laxative effect for newcomers
Chloride250 mg/LAestheticMay signal road salt or septic influence
Total dissolved solids (TDS)500 mg/LAestheticTaste and scale; consider reverse osmosis for drinking water
pH6.5-8.5Aesthetic and corrosionLow pH can corrode pipes; consider neutralizing treatment
Sodium20 mg/L (guidance for very low-sodium diets)DietaryRelevant if a doctor has limited your sodium
HardnessNo health limitAestheticSee hard well water

Hardness at a glance

Hardness (mg/L as calcium carbonate)Classification
0-60Soft
61-120Moderately hard
121-180Hard
Over 180Very hard

An Example Report, Line by Line

Here is an illustrative report excerpt. The numbers are made up to show how to read a real one.

AnalyteResultUnitsReporting limitReference limitFlag
Total coliformPresentP/An/aAbsentExceeds
E. coliAbsentP/An/aAbsentOK
Nitrate (as N)6.2mg/L0.110OK
Arsenic0.014mg/L0.0010.010Exceeds
Iron0.8mg/L0.050.3Exceeds (secondary)
ManganeseNDmg/L0.010.05OK
Hardness210mg/L5noneVery hard
pH7.1pH unitsn/a6.5-8.5OK

What this example tells us:

  • Total coliform present, E. coli absent. Surface contamination may be reaching the well. Treat the water as unsafe to drink untreated, disinfect the system, and retest. See Coliform Bacteria in Well Water.
  • Nitrate at 6.2 mg/L. Below the limit, but worth watching. Retest next year and look for an upward trend.
  • Arsenic 0.014 mg/L (14 µg/L). Above the 10 µg/L limit. Stop drinking the water or use a certified treatment option, and consult your health department.
  • Iron 0.8 mg/L. Above the aesthetic limit. Expect staining and metallic taste. This is treatable.
  • Manganese ND. Not detected at the lab’s 0.01 mg/L reporting limit.
  • Hardness 210 mg/L. Very hard. Scale buildup is likely, and a softener may help.
  • pH 7.1. Normal.

What «ND», «<«, and Other Marks Mean

MarkMeaning
NDNot detected: below the lab’s detection limit
< 0.5Less than the reporting limit of 0.5: the lab cannot reliably measure below this
J or «estimated»The value is between the detection limit and the reporting limit and is approximate
«Holding time exceeded»The sample sat too long before analysis; the result may be unreliable
«Improper container» or «temperature exceeded»The sample may have been compromised; consider retesting
«Exceeds» or an asteriskThe result is above the reference limit shown

The reporting limit matters. «ND» is reassuring only if the lab can detect amounts below the level of concern. For a contaminant with a very low limit, ask the lab whether its sensitivity is adequate.

How to Interpret Your Report Step by Step

  1. Confirm the sample details. Name, address, date, and sample location should be right.
  2. Look for flags and notes. Read any warnings first.
  3. Check the units of every result before comparing it to a limit.
  4. Compare each result with its reference limit using the chart above, and note whether the limit is health-based or aesthetic.
  5. Read «ND» and «<» in context by checking the reporting limit.
  6. Compare with earlier reports. A result below the limit but rising each year is a signal to investigate.
  7. Sort the results into green, yellow, and red using the table below.
  8. Decide what to do next, and when to retest.

Green, Yellow, and Red: A Simple Triage

CategoryWhat it looks likeWhat to do

| | Green | All results below limits; bacteria absent | Keep the report, retest on schedule. See How Often Should You Test Your Well Water? | | Yellow | Aesthetic limits exceeded (iron, manganese, hardness, sulfate, TDS, pH), or a health result approaching its limit | Not an emergency. Identify the cause, consider treatment, and retest. See Best Whole House Water Filter for Well Water | | Red | Bacteria present, or any health-based limit exceeded (nitrate, arsenic, uranium, VOCs, lead, PFAS) | Act promptly: use safe alternative water for drinking and cooking as advised, contact your health department, and pursue treatment or repair |

After any treatment or repair, retest to confirm the problem is solved.

Matching Results to Solutions

ResultTypical treatment approach (confirm with a professional)
BacteriaDisinfect the well and fix entry points; sometimes continuous treatment such as UV
NitrateReverse osmosis or ion exchange; see Is Reverse Osmosis Worth It for Well Water?
ArsenicTreatment chosen after identifying the form of arsenic present
HardnessWater softener; see Water Softener vs Water Conditioner
Iron and manganeseOxidizing filter or iron filter; see Iron Filter vs Water Softener
Low pHNeutralizing filter
VOCs, PFAS, radiologicalSpecialized treatment after professional evaluation

For pricing, see How Much Does a Whole House Water Filtration System Cost?

When to Retest or Get a Second Opinion

  • After any treatment, repair, or disinfection.
  • When a bacteria result is positive, retest following your health department’s instructions.
  • When a result is surprising, such as a first-ever arsenic or nitrate detection. Contamination can change over time, and a repeat sample from a fresh collection can confirm it.
  • When the lab flags a handling problem.
  • When home test strips and the lab disagree. Trust the certified lab. See Well Water Test Kit vs Lab Test.

Frequently Asked Questions

What is a safe level of contaminants in well water?

There is no legal standard for private wells, but EPA drinking water standards for public systems are widely used as benchmarks. See the chart above, and check whether your state offers its own guidance.

What does ND mean on a water test?

ND means not detected. The contaminant was below the level the lab can measure. Check the reporting limit to judge how reassuring that is.

What is the difference between mg/L and ppm?

For water, they are equal. One mg/L is one part per million (ppm). Similarly, µg/L equals ppb and ng/L equals ppt.

Is my water safe if it only exceeds a secondary standard?

Usually, yes. Secondary standards are about taste, odor, color, and staining, not health. Exceeding them can still damage plumbing and appliances, so treatment may be worthwhile.

My nitrate result is 40. Is that a problem?

It depends on the form. If it is reported as nitrate-N, 40 mg/L is four times the 10 mg/L limit and is serious. If it is reported as nitrate (NO₃), 40 mg/L is about 9 mg/L as nitrogen, just under the limit. Check the unit line on your report, and ask the lab if you are unsure.

Does boiling fix a bad result?

Boiling kills bacteria, but it does not remove nitrate, metals, or most chemicals, and it can concentrate them. It is an emergency measure for bacteria only.

How long should I keep my reports?

Keep them for as long as you own the well. A series of reports shows trends, and they are useful when you sell the home. See Well Water Testing for Real Estate Transactions.

Who can help me interpret the results?

Start with the lab, which can explain the report. Your county or state health department can explain health implications and next steps, and a licensed water treatment professional can advise on treatment.

Final Thoughts

Reading a well water report comes down to four things: the number, the unit, the limit, and what kind of limit it is. Sort results into green, yellow, and red, act promptly on anything red, plan treatment for yellow, and retest after every fix.

Next step: if your results need work, compare options in Best Whole House Water Filter for Well Water, and plan your next test with How Often Should You Test Your Well Water?

Disclaimer: This article is for general information only and is not medical or legal advice. Standards and recommendations change and vary by state and local conditions. For health concerns or a positive test result, consult your local or state health department and a qualified professional.

Sources to cite and link when publishing (verify current versions): EPA National Primary and Secondary Drinking Water Regulations; EPA Private Drinking Water Wells; CDC Private Well Testing guidance; USGS water hardness reference; your state health department’s guidance for private wells.

Deja un comentario

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *

Scroll al inicio